E16x442

Monitoring and Protection System E16x442 for increased safety requirements up to SIL2

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1665 and one Test Interface E1691
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • External test of a 2oo3 solenoid valve block possible via the control system
  • Minimal Total Cost of Ownership
  • Requires less than 8% of the permissible PFD value for a SIL2 Safety Loop
  • Replacement of all active components during operation (hot-swap)
  • SIL2 / IEC 61508:2010 compliant
  • API670 and API612 compliant
  • 1 PROFIBUS Interface

test

Details
E16x4422023-06-02T12:06:41+01:00

E16x452

Monitoring and Protection System E16x452 for increased safety requirements up to SIL2

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1666 and one Test Interface E1691
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • External test of a 2oo3 solenoid valve block possible via the control system
  • Minimal Total Cost of Ownership
  • Requires less than 8% of the permissible PFD value for a SIL2 Safety Loop
  • Replacement of all active components during operation (hot-swap)
  • SIL2 / IEC 61508:2010 compliant
  • API670 and API612 compliant
  • 2 PROFIBUS Interfaces

Details

E16x4522021-11-15T14:57:42+01:00

E16x446

Monitoring and Protection System E16x446 for increased safety requirements up to SIL2

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1665 and one Test Generator E1697
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
  • Minimal Total Cost of Ownership
  • Requires less than 1% of the permissible PFD value for a SIL2 Safety Loop
  • Enhanced safety values due to an integrated test generator
  • Replacement of all active components during operation (hot-swap)
  • SIL2 / IEC 61508:2010 compliant
  • API670 and API612 compliant
  • 1 PROFIBUS Interface

Details

E16x4462021-11-15T14:58:20+01:00

E16x456

Monitoring and Protection System E16x456 for increased safety requirements up to SIL2

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1666 and one Test Generator E1698
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
  • Minimal Total Cost of Ownership
  • Requires less than 1% of the permissible PFD value for a SIL2 Safety Loop
  • Enhanced safety values due to an integrated test generator
  • Replacement of all active components during operation (hot-swap)
  • SIL2 / IEC 61508:2010 compliant
  • API670 and API612 compliant
  • 2 PROFIBUS Interfaces

Details

E16x4562021-11-15T14:59:03+01:00
Go to Top