E16x342

Monitoring and Protection System E16x342 for highest safety requirements up to SIL3

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1667 and one Test Interface E1691
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • External test of a 2oo3 solenoid valve block possible via the control system
  • Minimal Total Cost of Ownership
  • Requires less than 8% of the permissible PFD value for a SIL3 Safety Loop
  • Replacement of all active components during operation (hot-swap)
  • TÜV certified for SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
  • TÜV certified for SILCL3 / IEC 62061:2005
  • API670 and API612 compliant
  • 1 PROFIBUS Interface

Details
E16x3422023-06-02T12:10:36+01:00

E16x352

Monitoring and Protection System E16x352 for highest safety requirements up to SIL3

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1668 and one Test Interface E1691
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • External test of a 2oo3 solenoid valve block possible via the control system
  • Minimal Total Cost of Ownership
  • Requires less than 8% of the permissible PFD value for a SIL3 Safety Loop
  • Replacement of all active components during operation (hot-swap)
  • TÜV certified for SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
  • TÜV certified for SILCL3 / IEC 62061:2005
  • API670 and API612 compliant
  • 2 PROFIBUS Interfaces

Details
E16x3522023-06-02T12:16:49+01:00

E16x346

Monitoring and Protection System E16x346 for highest safety requirements up to SIL3

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1667 and one Test Generator E1697
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
  • Minimal Total Cost of Ownership
  • Requires less than 1% of the permissible PFD value for a SIL3 Safety Loop
  • Enhanced safety values due to an integrated test generator
  • Replacement of all active components during operation (hot-swap)
  • TÜV certified for SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
  • TÜV certified for SILCL3 / IEC 62061:2005
  • API670 and API612 compliant
  • 1 PROFIBUS Interface

Details
E16x3462023-06-02T12:18:29+01:00

E16x356

Monitoring and Protection System E16x356 for highest safety requirements up to SIL3

  • TMR (triple-modular-redundant) system with sensor monitoring and self-test
  • The Protection System includes three Monitors E1668 and one Test Generator E1698
  • Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
  • Maintenance-free during lifetime due to integrated automatic proof tests
  • Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
  • Minimal Total Cost of Ownership
  • Requires less than 1% of the permissible PFD value for a SIL3 Safety Loop
  • Enhanced safety values due to an integrated test generator
  • Replacement of all active components during operation (hot-swap)
  • TÜV certified for SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
  • TÜV certified for SILCL3 / IEC 62061:2005
  • API670 and API612 compliant
  • 2 PROFIBUS Interfaces

Details
E16x3562023-06-02T12:19:53+01:00
Go to Top