A5S1DD0

Sensor A5S1DD0 for detection of rotational speed in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Single Channel, the output displays the rotational speed as a single-track frequency signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX, UKEX, IECEx certified for Ex ia IIC T4/T6 Ga
    • QPS / QPSus certified for Class I, Div 1, Groups A, B, C, D according to UL and CSA standards
    • EAC certified for Ex ia IIC T4/T6 Ga

ukca test

Details
A5S1DD02023-06-02T12:38:34+01:00

A5S1DD3

Sensor A5S1DD3 for detection of rotational speed and direction of rotation in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Dual Channel, 1 track = rotational speed as frequency, 1 track = F/R status as binary signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX, UKEX, IECEx certified for Ex ia IIC T4/T6 Ga
    • QPS / QPSus certified for Class I, Div 1, Groups A, B, C, D according to UL and CSA standards
    • EAC certified for Ex ia IIC T4/T6 Ga

ukca test

Details
A5S1DD32023-06-02T12:40:00+01:00

A5S1DD4

Sensor A5S1DD4 for detection of rotational speed and direction of rotation with two phase-shifted speed signals in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Dual Channel, the output displays the rotational speed as a twin-track frequency signal (phase-shifted)
  • Suitable for external direction detection with enhanced safety
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX, UKEX, IECEx certified for Ex ia IIC T4/T6 Ga
    • QPS / QPSus certified for Class I, Div 1, Groups A, B, C, D according to UL and CSA standards
    • EAC certified for Ex ia IIC T4/T6 Ga

ukca test

Details
A5S1DD42023-06-02T12:41:20+01:00

A5S1DS0

Sensor A5S1DS0 for detection of rotational speed in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Single Channel, the output displays the rotational speed as a single-track frequency signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX, UKEX, IECEx certified for Ex ia IIC T4/T6 Ga
    • QPS / QPSus certified for Class I, Div 1, Groups A, B, C, D according to UL and CSA standards
    • EAC certified for Ex ia IIC T4/T6 Ga

ukca test

Details
A5S1DS02023-06-02T12:42:41+01:00

A5S1DS3

Sensor A5S1DS3 for detection of rotational speed and direction of rotation in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Dual Channel, 1 track = rotational speed as frequency, 1 track = F/R status as binary signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX, UKEX, IECEx certified for Ex ia IIC T4/T6 Ga
    • QPS / QPSus certified for Class I, Div 1, Groups A, B, C, D according to UL and CSA standards
    • EAC certified for Ex ia IIC T4/T6 Ga

ukca test

Details
A5S1DS32023-06-02T12:43:51+01:00

A5S1DS4

Sensor A5S1DS4 for detection of rotational speed and direction of rotation with two phase-shifted speed signals in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Dual Channel, the output displays the rotational speed as a twin-track frequency signal (phase-shifted)
  • Suitable for external direction detection with enhanced safety
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX, UKEX, IECEx certified for Ex ia IIC T4/T6 Ga
    • QPS / QPSus certified for Class I, Div 1, Groups A, B, C, D according to UL and CSA standards
    • EAC certified for Ex ia IIC T4/T6 Ga

ukca test

Details
A5S1DS42023-06-02T12:45:13+01:00

D461R1

Isolating Barrier D461R1 for A5S1... Ex ia sensors in Hazardous Areas Zone 0-1

  • For use in connection with A5S1... Ex ia series sensors a highly efficient system for detecting rotational speed (and direction of rotation) in areas of explosion risk
  • Provides intrinsic safety for the sensor and its cabling
  • Enhanced output signal for use by electronic measuring devices
  • Implementation outside the Hazardous Area, resp. protected by a pressure-resistant encapsulated housing
  • Certification
    • ATEX as Ex ia Ga IIC
    • UKEX as Ex ia Ga IIC
    • IECEx as Ex ia Ga IIC
    • KCs as Ex ia Ga IIC
    • QPS / QPSus as Ex ia Ga IIC for Class I, Div 1, Groups A, B, C, D according to UL and CSA standards

ukca test

Details